Ara
Toplam kayıt 2, listelenen: 1-2
Modified Induction Machine Equivalent Circuit Including Solid Shaft Eddy Currents
(MDPI, 2023)
The shaft eddy currents cause a significant saturation in two-pole induction machines
(IMs) as they generate an opposing field and repulse the main flux, thus tightening the flux path.
This results in inaccurate performance ...
Investigating the Role of Stator Slot Indents in Minimizing Flooded Motor Fluid Damping Loss
(MDPI, 2023)
This research examines how fluid damping loss affects the operation of a two-pole, 5.5 HP
(4 kW) induction machine (IM) within the context of different slot opening configurations developed
for downhole water pump ...