dc.contributor.authorHah, Dooyoung
dc.date.accessioned2020-02-03T08:40:00Z
dc.date.available2020-02-03T08:40:00Z
dc.date.issued2019en_US
dc.identifier.issn1300-0632
dc.identifier.other1303-6203
dc.identifier.other10.3906/elk-1901-233
dc.identifier.urihttps://hdl.handle.net/20.500.12573/96
dc.descriptionThis work was partially supported by the Research Fund of Abdullah Gul University (Project Number: FOA-2016-49).en_US
dc.description.abstractIntravascular ultrasonography (IVUS), a medical imaging modality, is used to obtain cross-sectional views of blood vessels from inside. In IVUS, transducers are brought to the proximity of the imaging targets so that high-resolution images can be obtained at high frequency without much concern of signal attenuation. To eliminate mechanical rotation rendered in conventional IVUS, it is proposed to manufacture a transducer array on a flexible substrate and wrap it around a cylindrical frame. The transducer of consideration is a capacitive micromachined ultrasonic transducer (CMUT). The whole device needs to be made out of polymers to be able to endure a high degree of bending (radius: 1 mm) Bending of the devices leads to considerable changes in the device characteristics, including resonant frequency and pull-in voltage due to geometrical dimension changes and stress induced. The main purpose of this work is to understand the effect of bending on the device characteristics by means of finite element analysis. Another objective of the work is to understand the relationships between such an effect and the device geometries. It is learned that the bending-induced stress depends strongly on anchor width, membrane thickness, and substrate thickness. It is also learned that resonant frequency and pull-in voltage become lower in most cases because of using a flexible substrate in comparison to those of the device on a rigid substrate. Bending-induced stress increases the spring constant and hence increases resonant frequency and pull-in voltage, although this effect is relatively weaker. For most of the device geometries, pull-in voltage is too high for the polymer material to endure. This is the main drawback of the all-polymer CMUT. In order to meet the design goal of 20 MHz resonant frequency, the membrane radius has to be smaller than 7.7 mu m for a thickness of 3 mu m.en_US
dc.description.sponsorshipAbdullah Gul University FOA-2016-49en_US
dc.language.isoengen_US
dc.publisherTUBITAK SCIENTIFIC & TECHNICAL RESEARCH COUNCIL TURKEY, ATATURK BULVARI NO 221, KAVAKLIDERE, ANKARA, 00000, TURKEYen_US
dc.relation.ispartofseries27;
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPolymer microelectromechanical systemsen_US
dc.subjectultrasonic transduceren_US
dc.subjectflexible substrateen_US
dc.subjectintravascular ultrasonographyen_US
dc.titleAll-polymer ultrasonic transducer design for an intravascular ultrasonography applicationen_US
dc.typearticleen_US
dc.contributor.departmentAGÜ, Mühendislik Fakültesi, Elektrik & Elektronik Mühendisliği Bölümüen_US
dc.contributor.institutionauthorHah, Dooyoung
dc.identifier.doi10.3906/elk-1901-233
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster