Passive Flow Control Application Using Single and Double Vortex Generator on S809 Wind Turbine Airfoil
Özet
The current study is aimed at investigating the influences of vortex generator (VG) applications mounted to the suction and pressure surfaces of the S809 wind turbine airfoil at low Reynolds
number flow conditions. Both single and double VG applications were investigated to provide
technological advancement in wind turbine blades by optimizing their exact positions on the surface
of the airfoil. The results of the smoke-wire experiment for the uncontrolled case reveal that a laminar
separation bubble formed near the trailing edge of the suction surface, and it was moved towards
the leading edge as expected when the angle of attack was increased, resulting in bubble burst and
leading-edge flow separation at α = 12◦
. The u/U∞, laminar kinetic energy and total fluctuation
energy contours obtained from the numerical study clearly show that both the single and double
VG applications produced small eddies, and those eddies in the double VG case led the flow to be
reattached at the trailing edge of the suction surface and to gain more momentum by energizing.
This situation was clearly supported by the results of aerodynamic force; the double VG application
caused the lift coefficient to increase, resulting in an enhancement of the aerodynamic performance.
A novel finding is that the VG at the pressure surface caused the flow at the wake region to gain more
energy and momentum, resulting in a reattached and steadier flow condition.