A distinctive determination of circular nozzles in downcomer for column flotation
Özet
This study aims to recover clean coal from valuable hard coal tailings (HCT), which have been used as solid fuels in a thermal power plant, through convenient conditions. The effective diameters of circular nozzles on the recovery of HCT were investigated by using the Jameson cell (JC) as the main purpose. Preliminary tests were conducted to determine the type and dosages of the collector and frother. The JC test results were evaluated by Yates and Box Behnken based on ANOVA analysis, statistically. It was observed that 3,000 g/ton of diesel oil, 300 g/ton of MIBC, 100 g/ton of Na2SiO3, and 60 cm of downcomer depth were found applicable levels of parameters. The decrease of the diameter increased the venturi effect of downcomer which provided the best recovery ratio of 97.79%. Besides, the results of kinetic models were obtained with desired efficiencies (CR∞ = 94.77%, k coal = 1.20, R 2 = 0.98 and SI = 2.40). The best diameter was 5 cm supplied a short time and high carrying capacity (CC) for concentrate.